Display type Digital
Measured parameter AC current, AC voltage, Capacitance, Continuity check, DC current, DC voltage, Diode check, Frequency, Resistance, Temperature [...]
Detection method True RMS
AC current measuring range 600µA, 6000µA, 60mA, 440mA, 6A, 10A
DC current measuring range 600µA, 6000µA, 60mA, 440mA, 6A, 10A
Standard accessories Battery: R6 x 4 pc, Fuse: 8926, Fuse: 8927, Test leads: 7220A
Separately accessories Battery: R6, AC/DC clamp sensor: 8115, Alligator clips: 7234, Clamp se nsor: 8121, Clamp sensor: 8122, Clamp sensor: 8123, Clamp sensor: 8146, Clamp sensor: 8147, Clamp sensor: 8148, Banana Ø4mm adjuster plug: 7146, Carrying case: 9154, Temperature probes: 8405, Temperature probes: 8406, Temperature probes: 8407, Temperature probes: 8408 [...]
Type Multimeter
Display digits 4 digits
Display features LCD display
Frequency measuring range 10...99.99Hz, 90...999.9Hz, 0.9...9.999kHz, 9...99.99kHz
Frequency measurement range - Accuracy 10...99.99Hz - ±02%rdg. ±1dgt., 90...999.9Hz - ±02%rdg. ±1dgt., 0.9... 9.999kHz - ±02%rdg. ±1dgt., 90...99.99kHz - ±02%rdg. ±1dgt. [...]
AC voltage measuring range 600mV, 6V, 60V, 600V, 1000V
AC voltage measurement range - Accuracy 600mV - ±0.5% rdg ±5 dgt [50/60Hz], 6V - ±0.5% rdg ±5 dgt [50/60Hz], 6 0V - ±0.5% rdg ±5 dgt [50/60Hz], 600V - ±0.5% rdg ±5 dgt [50/60Hz], 1000V - ±0.5% rdg ±5 dgt [50/60Hz] [...]
AC current measurement range - Accuracy 600µA - ±0.75% rdg. ±5 dgt. [50/60Hz], 6000µA - ±0.75%rdg. ±5dgt. [50/ 60Hz], 60mA - ±0.75%rdg. ±5dgt. [50/60Hz], 440mA - ±0.75%rdg. ±5dgt. [50/60Hz], 6A - ±0.75%rdg. ±5dgt. [50/60Hz], 10A - ±0.75%rdg. ±5dgt. [50/60Hz] [...]
DC voltage measuring range 600mV, 6V, 60V, 600V, 1000V
DC voltage measurement range - Accuracy 600mV - ±09%rdg. ±2dgt., 6V - ±09%rdg. ±2dgt., 60V - ±09%rdg. ±2dgt., 600V - ±09%rdg. ±2dgt., 1000V - ±0.15%rdg. ±2dgt. [...]
DC current measurement range - Accuracy 600µA - ±0.2%rdg. ±2dgt., 6000µA - ±0.2%rdg. ±2dgt., 60mA - ±0.2%rdg. ±2dgt., 440mA - ±0.5%rdg. ±5dgt., 6A - ±0.5%rdg. ±5dgt., 10A - ±0.5%rdg. ±5dgt. [...]
Resistance measuring range 600Ohm, 6kOhm, 60kOhm, 600KOhm, 6MOhm, 60MOhm
Resistance measurement range - Accuracy 600Ohm - ±0.4%rdg. ±1dgt., 6kOhm - ±0.4%rdg. ±1dgt., 60kOhm - ±0.4%rdg . ±1dgt., 600kOhm - ±0.4%rdg. ±1dgt., 6MOhm - ±0.5%rdg. ±1dgt., 0…40MOhm - ±1%rdg. ±2dgt., 40…60MOhm - ±2%rdg. ±2dgt. [...]
Capacitance measuring range 10nF, 100nF, 1µF, 10µF, 100µF, 1000µF
Capacitance measurement range - Accuracy 10nF - ±2%rdg.±10dgt., 100nF - ±2%rdg.±5dgt., 1µF - ±2%rdg.±5dgt., 10µ F - ±2%rdg.±5dgt., 100µF - ±3%rdg.±5dgt., 1000µF - ±3%rdg.±5dgt. [...]
Temperature measuring range -50...600ºC (Temperature probe sold separately)
Temperature measurement range - Accuracy -50...600ºC - ±2%rdg ±2ºC
Battery requires AA size (1.5 V)
Continuous operating time 300hours
Test end Probe tip
Alarm signal type Sound
Feature Back light, Bar indicator, Zero adjustment (Capacitor, Resistance)
, Auto power save function (APS), Data hold function, Filter, Auto hold, Min./Max. mode, Range hold [...]
Protective function Fuse, Overload protection
Safety rating CAT III (1,000V), CAT IV (600V)
Mounting method Hand held
Operation ambient Indoor
Ambient temperature -10…50°C
Ambient humidity 80% max.
Approx. weight 560g
Overall width 90mm
Overall height 192mm
Overall depth 49mm
Representative standard CE, EMC